The AZ-15
type suck-in unit is used to suck in air and non-aggressive
industrial gases not requiring flameproof
protection. It suitable for co-operation with
gravimetric dust meters for dust emissions, as
well as EMIOTESTR
and EMITEST. It can be used also in
other sets for measurement of gas emission.

Design and
operation
The unit
contains an oil-free rotatory blade pump made of
cast iron material and driven directly by a
single-phase induction motor. The pump consists
of a cylindrical body (1) closed with a cover (2)
in which a suck-in impeller (3) is fitted
eccentrically on the extended shaft of the motor.
The impeller has four symmetrically located slots
along the whole length in which blades are fitted
(4). The blades supplied by LE CARBONE - LORRAINE
company (France) are made of a special self-lubricating
composite. During a rotation, the impeller blades
move out as a result of centrifugal force and
they slide on cylinder coating (1).
Eccentric settlement of the impeller
against the cylinder brings about the effect of
sucking in the gas agent from the inlet stub (5)
to the outlet stub (6). There is an acoustic
exhaust damper (7) fitted on the outlet stub.
There is a ball cut-off valve fitted on the inlet
stub. The unit motor (8) is equipped with an
electric circuit breaker (9) interlocked with the
start-up condenser and mains socket for
connection of the supply cable provided with a
plug including a protecting contact. The motor is
protected from overload with a thermal switch
fitted in the impeller winding.

Design
of the AZ-15 suck-in unit.
Application of
the unit
Finishing
running on the user's premises is not required
because the pump is delivered already after the
finishing run at the manufacturer's. The pump can
be immediately used for normal operation.
The unit should be used in a place not
exposed to direct atmospheric precipitation.
Connection to the 220-230 V / 50 Hz mains
should be made through a protective differential
current circuit breaker. Fluctuation of 220 V
power supply voltage cannot exceed 10 % of the
nominal voltage. With voltage fluctuation above
10 % the unit should not be started.
Do
not use the pump with the completely closed
aspiration route.
The pump
body warms up on its own as a result of friction,
however even when the gas at high temperature is
sucked in there is no risk of pump overheating.
In case the acceptable temperature is exceeded,
the unit will be switched off automatically. When
cooled down, the unit can be started again.
After the end of operation the pump should
be "blown" with atmospheric air for
minimum time of 15 min. to clean and dry
interior of the pump.
Good quality of materials used to make the
pump and careful processing of details ensure
that the pump utilised according to these
recommendations is a stable and reliable piece of
equipment.
Periodically (after approx. 5 hours of pump
operation) condition of the exhaust damper should
be examined. In the case of contamination, it
should be removed and cleaned.
Basic technical
data
| - pump |
rotation,
dry, 4-blade pump |
| - motor |
inductive,
single-phase with capacity |
| |
0,55 kW;
1380 rpm |
| -
temperature of the gas being sucked in |
up to 100 °C |
| -
constant operation time |
up to 8
hours |
| - unit
weight |
19,5 kg |
| - unit
dimensions |
0,33 x 0,16
x 0,28 m |
| -
internal diameter of the flexible suck-in
hose |
10 ÷ 12 mm |

Example
of AZ-15 unit characteristics.
|